ENGLISH

Advanced Concepts for Renewable Energy Supply of Data Centres (River Publishers Series in Renewable Energy)

Book information

Publisher
River Publishers
Year
2017
ISBN
8793519427, 9788793519428
Language
english
Format
PDF
Filesize
52 MB (54213770 bytes)
Pages
320\338
Time added
2021-10-17 18:25:18

Description

The rapid increase of cloud computing, high performance computing (HPC) and the vast growth in Internet and Social Media use have aroused the interest in energy consumption and the carbon footprint of Data Centers. Data Centers primarily contain electronic equipment used for data processing (servers), data storage (storage equipment), and communications (network equipment). Collectively, this equipment processes, stores, and transmits digital information and is known as information technology (IT) equipment. Advanced Concepts for Renewable Energy Supply of Data Centres introduces a number of technical solutions for the supply of power and cooling energy into Data Centers with enhanced utilization of renewable energy sources in order to achieve low energy Data Centers. Because of the high energy density nature of these unique infrastructures, it is essential to implement energy efficiency measures and reduce consumption before introducing any renewable energy source. A holistic approach is used with the objective of integrating many technical solutions such as management of the IT (Information Technology) load, efficient electrical supply to the IT systems, Low-Ex air-conditioning systems, interaction with district heating and cooling networks, re-use of heat, free cooling (air, seawater, groundwater), optimal use of heat and cold storage, electrical storage and integration in smart grids. This book is therefore a catalog of advanced technical concepts that could be integrated into Data Centers portfolios in order to increase the overall efficiency and the share of renewable energies in power and cooling supply. Based on dynamic energy models implemented in TRNSYS, some concepts are deeply evaluated through yearly simulations. The results of the simulation are illustrated with Sankey charts, where the energy flows per year within the subsystems of each concept for a selected scenario are shown, and graphs showing the results of parametric analysis. A set of environmental metrics (as the non-renewable primary energy) and financial metrics (CAPEX and OPEX) as well of energy efficiency metrics like the well-known PUE, are described and used to evaluate the different technical concepts. Front Cover Half Title Page RIVER PUBLISHERS SERIES IN RENEWABLE ENERGY Title Page - Advanced Concepts for Renewable Energy Supply of Data Centres Copyright Page Contents Preface Acknowledgments List of Contributors List of Figures List of Tables List of Symbols and Abbreviations Chapter 1 -Data Centre Overview 1.1 Data Centre Infrastructure 1.1.1 Introduction 1.2 Main Subsystems 1.2.1 IT Equipment 1.2.2 Power System 1.2.3 Cooling System 1.3 Data Centre Archetypes 1.3.1 Function or Objective of the Data Centre 1.3.2 Size 1.3.3 Location and Surroundings 1.3.4 Archetypes Definition 1.4 Workload Typology 1.4.1 WebWorkloads 1.4.2 HPCWorkloads 1.4.3 DataWorkloads 1.4.4 Consumption versusWorkload Typology 1.5 Redundancy Level 1.5.1 Basic Definitions 1.5.2 Tier Levels 1.6 Future Trends References Chapter 2 - Operational Requirement 2.1 Working Temperature Limit 2.1.1 Impact of Server Inlet Temperature 2.1.2 Permitted Temperatures of Individual Components 2.1.3 CPU Power Management and Throttling 2.2 Environmental Conditions 2.2.1 Temperature and Humidity Requirements 2.2.2 Quality of the Room Air 2.3 Power Quality 2.3.1 Input Voltage within Acceptable Limits 2.3.2 Input Frequency within Allowable Ranges 2.3.3 Sufficient Input Power to Compensate for Power Factor 2.3.4 Transfer to Backup Power Faster than PSU “Hold-up”Time 2.3.5 Protection from Damaging Power Conditions References Chapter 3 - Environmental and Economic Metrics for Data Centres 3.1 About Metrics in Data Centres 3.2 Data Centre Boundaries for Metrics Calculation 3.2.1 Definition of Boundaries 3.2.2 Energy Flows 3.3 Metrics for Cost-Environmental Analysis 3.3.1 Environmental Impact Metrics 3.3.1.1 Data Centre primary energy 3.3.1.2 Data Centre CO2 emissions 3.3.1.3 Data Centre water consumption 3.3.2 Financial Metrics 3.3.2.1 Methodological reference framework 3.3.2.2 Global cost 3.3.2.3 CAPEX: capital expenditure 3.3.2.4 OPEX: operating expenditure 3.3.3 Cost-Efficiency Analysis 3.4 Energy Efficiency and Renewable Energy Metrics 3.4.1 Power Usage Effectiveness (PUE) 3.4.2 Renewable Energy Ratio 3.4.3 Renewable Energy Factor 3.5 Capacity Metrics 3.5.1 Introduction 3.5.2 Capacity Metrics 3.6 Examples 3.6.1 Example 1. PV System and Ice Storage 3.6.2 Example 2. District Cooling and Heat Reuse References Chapter 4 - Advanced Technical Concepts for Efficient Electrical Distribution and IT Management 4.1 Advanced Technical Concepts for Efficient IT Management 4.2 Advanced Technical Concepts for Efficient Electric Power Distribution 4.2.1 Introduction 4.2.2 Modular UPS 4.2.3 Bypassed UPS 4.2.4 Enhanced UPS for Electrical Energy Storage References Chapter 5 - Advanced Technical Concepts for Low-Exergy Climate and Cooling Distribution 5.1 Introduction 5.2 Free Cooling 5.2.1 Free Cooling with Direct Ambient Air 5.2.2 Free Cooling with Indirect Ambient Air 5.2.3 Seawater Air Conditioning System 5.2.4 Free Cooling with Groundwater 5.3 Increasing Allowable IT Temperatures 5.3.1 Increased White Space Temperature with Airside Cooling 5.3.2 Increased White Space Temperature with Chilled Water Cooling 5.3.3 Increasing the Delta T Through the IT Equipment 5.4 Hot or Cold Aisle Containment 5.5 Variable Airflow 5.5.1 Strategy A: Pressure Difference 5.5.2 Strategy B: Actual IT load 5.5.3 Strategy C: Return Air Temperature 5.6 Partial Load – Redundant or Oversized Components 5.6.1 Redundant Components and Oversizing Components 5.6.2 Partial Load with Chillers 5.6.3 Variable Flow with Fans and Pumps 5.6.4 Oversizing Dry Coolers and Cooling Towers 5.6.5 Energy Savings and Payback Periods 5.7 High Energy Efficiency Components 5.7.1 Fans and Pumps 5.7.2 Air-Cooled Chillers 5.7.3 Water-Cooled Chillers 5.8 Conclusions References Chapter 6 - Advanced Technical Concepts for Power and Cooling Supply with Renewables 6.1 Introduction 6.1.1 Concepts Overview 6.1.1.1 Sankey charts analysis 6.2 Description of the Proposed Advanced Technical Concepts 6.2.1 Photovoltaic System and Wind Turbines with Vapour-Compression Chiller and Lead-Acid Batteries 6.2.2 District Cooling and Heat Reuse 6.2.3 Grid-FedWet Cooling Tower Without Chiller 6.2.4 Grid-Fed Vapour-Compression Chiller with Electrical Energy and Chilled Water Storages 6.2.5 Biogas Fuel Cell with Absorption Chiller 6.2.6 Reciprocating Engine CHP with Absorption Chiller References Chapter 7 - Applying Advanced Technical Concepts to Selected Scenarios 7.1 Overview of Concept Performance 7.2 Concept Comparison for Selected Scenarios 7.2.1 Description of Scenarios Analysed 7.3 Detailed Analysis by Advanced Technical Concepts 7.3.1 Introduction 7.3.2 Concept 1. Photovoltaic System and Wind Turbines with Vapour-Compression Chiller 7.3.2.1 Influence of energy efficiency measures 7.3.2.2 Influence of size 7.3.2.3 On-Site renewable energy systems implementation 7.3.3 Concept 2. District Cooling and Heat Reuse 7.3.3.1 Influence of energy efficiency measures 7.3.3.2 Influence of size 7.3.3.3 Influence of the liquid cooling solution and the potential heat reuse 7.3.4 Concept 3. Grid-FedWet Cooling Tower without Chiller 7.3.4.1 Influence of energy efficiency measures 7.3.4.2 Influence of EE measures 7.3.4.3 Influence of size 7.3.4.4 On-site PV systems implementation 7.3.5 Concept 4. Grid-Fed Vapour-Compression Chiller with Electrical Energy and ChilledWater Storages 7.3.5.1 Influence of EE measures 7.3.5.2 Influence of size 7.3.5.3 Influence of the size of TES 7.3.6 Concept 5. Biogas Fuel Cell with Absorption Chiller 7.3.6.1 Influence of EE measures 7.3.6.2 Influence of size 7.3.6.3 Influence of absorption chiller sizes and potential heat reuse 7.3.7 Concept 6. Reciprocating Engine CHP with Absorption Chiller 7.3.7.1 Influence of EE measures 7.3.7.2 Influence of size 7.3.7.3 Influence of absorption chiller sizes and potential heat reuse 7.4 Other Aspects Influencing Data Centre Energy Consumption 7.4.1 Influence of the IT Load Profile 7.4.1.1 Influence of the rack density, occupancy, and oversizing factors 7.5 The RenewIT Tool 7.6 Conclusion References Annexes Index About the Editors Back Cover

Similar books

Session C11: Ancient Cultural Landscapes in South Europe – their Ecological Setting and Evolution, Session C22: Gardeners from South America, Session S04: Agro-Pastoralism and Early Metallurgy Sessions, Session WS29: The Idea of Enclosure in Recent Iberian Prehistory, Session C88: Rhytmes et causalites des dynamiques de l'anthropisation en Europe entre 6500 ET 500 BC: Hypotheses socio-culturelles et/ou climatiques: Proceedings of the XV UISPP World Congress (Lisbon 4-9 September 2006) / Actes du XV Congrès Mondial (Lisbonne 4-9 Septembre 2006) Vol.36

Session C11: Ancient Cultural Landscapes in South Europe – their Ecological Setting and Evolution, Session C22: Gardeners from South America, Session S04: Agro-Pastoralism and Early Metallurgy Sessions, Session WS29: The Idea of Enclosure in Recent Iberian Prehistory, Session C88: Rhytmes et causalites des dynamiques de l'anthropisation en Europe entre 6500 ET 500 BC: Hypotheses socio-culturelles et/ou climatiques: Proceedings of the XV UISPP World Congress (Lisbon 4-9 September 2006) / Actes du XV Congrès Mondial (Lisbonne 4-9 Septembre 2006) Vol.36

2010 · PDF

THE BRITISH ARMY IN INDIA: ITS PRESERVATION BY AN APPROPRIATE CLOTHING, HOUSING, LOCATING, RECREATIVE EMPLOYMENT, AND HOPEFUL ENCOURAGEMENT OF THE TROOPS. with AN APPENDIX ON INDIA : THE CLIMATE OP ITS HILLS ; THE DEVELOPMENT OF ITS RESODRCBS, INDUSTRY, AND ARTS ; THE ADMINISTRATION OF JUSTICE ; THE BLACK ACT ; THE PROGRESS OF CHRISTIANITY ; THE TRAFFIC IN OPIUM ; THE VALUE OF INDIA ; PERMANENT CAUSES OF DISAFFECTION, AND OF THE RECENT REBELLION ; THE TRADITIONARY POLICY; MISGOVERNMENT BY NATIVE RULERS ; ANNEXATIONS OF THEIR TERRITORY, ETC.

THE BRITISH ARMY IN INDIA: ITS PRESERVATION BY AN APPROPRIATE CLOTHING, HOUSING, LOCATING, RECREATIVE EMPLOYMENT, AND HOPEFUL ENCOURAGEMENT OF THE TROOPS. with AN APPENDIX ON INDIA : THE CLIMATE OP ITS HILLS ; THE DEVELOPMENT OF ITS RESODRCBS, INDUSTRY, AND ARTS ; THE ADMINISTRATION OF JUSTICE ; THE BLACK ACT ; THE PROGRESS OF CHRISTIANITY ; THE TRAFFIC IN OPIUM ; THE VALUE OF INDIA ; PERMANENT CAUSES OF DISAFFECTION, AND OF THE RECENT REBELLION ; THE TRADITIONARY POLICY; MISGOVERNMENT BY NATIVE RULERS ; ANNEXATIONS OF THEIR TERRITORY, ETC.

1858 · PDF

Idries Shah 27 Books Collection : A Perfumed Scorpion, A Veiled Gazelle, Caravan of Dreams, Darkest England, Destination Mecca, Evenings with Idries Shah, Knowing How to Know, Learning How to Learn, Letters and Lectures of Idries Shah, Neglected aspects of Sufi study, Observations, Oriental Magic, Reflections, Seeker after Truth, Special Illumination, Special Problems in the study of Sufi ideas, Sufi thought and action, Tales of the Dervishes, The Dermis Probe, The Elephant in the Dark, The Englishman Handbook, Idries Shah Antology, The Magic Monastery, The natives are restless, wisdom of the Idiots PDF.

Idries Shah 27 Books Collection : A Perfumed Scorpion, A Veiled Gazelle, Caravan of Dreams, Darkest England, Destination Mecca, Evenings with Idries Shah, Knowing How to Know, Learning How to Learn, Letters and Lectures of Idries Shah, Neglected aspects of Sufi study, Observations, Oriental Magic, Reflections, Seeker after Truth, Special Illumination, Special Problems in the study of Sufi ideas, Sufi thought and action, Tales of the Dervishes, The Dermis Probe, The Elephant in the Dark, The Englishman Handbook, Idries Shah Antology, The Magic Monastery, The natives are restless, wisdom of the Idiots PDF.

2022 · PDF

The travels of Capts. Lewis and Clarke from St. Louis, by way of the Missouri and Columbia rivers, to the Pacific ocean; performed in the years 1804, 1805 & 1806, by order of the government of the United States. Containing delineations of the manners, customs, religion, &c. of the Indians, comp. from various authentic sources, and original documents, and a summary of the Statistical view of the Indian nations, from the official communication of Meriwether Lewis. Illustrated with a map of the country, inhabited by the western tribes of Indians

The travels of Capts. Lewis and Clarke from St. Louis, by way of the Missouri and Columbia rivers, to the Pacific ocean; performed in the years 1804, 1805 & 1806, by order of the government of the United States. Containing delineations of the manners, customs, religion, &c. of the Indians, comp. from various authentic sources, and original documents, and a summary of the Statistical view of the Indian nations, from the official communication of Meriwether Lewis. Illustrated with a map of the country, inhabited by the western tribes of Indians

1809 · PDF

Professional Linux kernel architecture ''Wrox programmer to programmer''--Cover. - ''What you are reading right now is the result of an evolution over more than seven years: After two years of writing, the first edition was published in German by Carl Hanser Verlag in 2003. It then described kernel 2.6.0. The test was used as a basis for the low-level design documentation for the EAL4+ security evaluation of Red Hat Enterprise Linux 5, requiring to update it to kernel 2.6.18 (if the EAL acronym does not mean anything to you, then Wikipedia is once more your friend). Hewlett-Packard sponsored the translation into English and has, thankfully, granted the rights to publish the result. Updates to kernel 2.6.24 were then performed specifically for this book''--P. ix

Professional Linux kernel architecture ''Wrox programmer to programmer''--Cover. - ''What you are reading right now is the result of an evolution over more than seven years: After two years of writing, the first edition was published in German by Carl Hanser Verlag in 2003. It then described kernel 2.6.0. The test was used as a basis for the low-level design documentation for the EAL4+ security evaluation of Red Hat Enterprise Linux 5, requiring to update it to kernel 2.6.18 (if the EAL acronym does not mean anything to you, then Wikipedia is once more your friend). Hewlett-Packard sponsored the translation into English and has, thankfully, granted the rights to publish the result. Updates to kernel 2.6.24 were then performed specifically for this book''--P. ix

2008 · PDF